Product Description

DESCRIPTION

Master Coat Clear - HD is a high build, heavy duty industrial coating based on epoxy resin and hardner.  Master Coat Clear - HD is especially developed to take the loads that are expected on the floors and walls, metal and concrete structures of a factory.  The product is supplied as two-pack system comprising of base and hardener.  It requires only on  site mixing to produce an easily applied chemical resistant finish.  Master Coat Clear - HD coating can be easily be built up to higher thickness by subsequent coats.

PRIMARY USE

For the external and internal protection of concrete or metal tanks containing drinking water oils, consumable liquids, etc.  Used as a protective coating in laboratories, abattoirs etc.

GUIDE TO APPLICATION

Ensure adequate ventilation during application.  Master Coat Clear - HD coatings of can be applied either using lambs wool rollers or short haired stiff bristled nylon brushes.  The second coat is applied on the second day of the first coat or at an interval of atleast eight hrs.

ADVANTAGES
1.  Durable

2.  Solvent Free

3.  Non-toxic

4.  High build coating

5.  Waterproof

6.  Chemical resistant

7.  Easily applied by brush or roller

PROPERTIES

Density 1500 kg/m3
Bond Strength In excess of cohesive strength of mortar
pot life 45 min at 35 C
Tack Free Time 6 hrs at 35 C
Initial/Full cure 24 hrs / 7 days
Shelf Life 6 mths
Specific Gravity 1.38 at 20 C
Dried Film thickness 200 microns per coat
Appearance Smooth and glossy
Chemcial Resistance Excellent

PACKING

1 kg and bulk

CHEMICAL RESISTANCE

Master Coat Clear - HD is resistant to the following typically encountered chemcials. Formaldehde 40% solution, Sulpheric Acid 30% solution. Wine, Acetic Acid 5% solution, Diesel-oil, Hydrochloric Acid 50% solution Aviation Hydraulic Fuels (Skydrol), Nitric Acid 10% solution and vegetable oils.

Master Coat Clear - HD coating may slightly change color in certain chemical environments but the chemical resistance of the Master Coat Clear - HD film remains unchanged.

OVERCOATING

Where areas need to be over coated due to damage etc., It is important that the area to be treated is well abraded using stiff rotary wire brush or coarse sand paper to give adequate key. Completely strip off any unsound coating and proceed with over coating as for new work.

DIRECTIONS FOR USE

Surface Preparation:

The Substrate should be a smooth or semi-smooth sound surface such as concrete or metal. It is most important to ensure that thorough surface preparation is undertaken prior to application of the Master Coat Clear - HD Coating.

Concrete :

Ensure concrete is free from excessive laitance, grease, oil, curing compound, etc. Ensure concrete is sound. Cut back wherever necessary and make good using suitable cementitious or epoxy repair system. Ensure all blow holes and surface imperfections are made good prior to application of the coating. Wire brushing followed by degreasing, acid etching or grit blasting may be necessary to remove laitance. Ensure concrete is atleast 28 days old.

Steel:

All previous surface treatments should be removed taking the surface back to base metal. The base metal should be abraded and preferably shot blasted. Cleaning with solvent or a strong detergent is advisable to ensure surface is free from grease etc. Do not allow surface to re-oxidise before application of Master Coat Clear- HD.

Mixing:

Master Coat Clear - HD  is supplied in two pre-weighted components, Base and reactor. No additions or omissions are required. Add reactor contents to the base components and stir thoroughly for 3-4 minutes using a slow speed hand drill fitted with a paddle. Mix until a uniform colour is achieved. Apply in two coats.

EQUIPEMENT CARE

All equipment must be cleaned immediately after use with cleaning solvents. Similar procedures should be adopted for break periods exceeding fifteeen minutes.

COVERAGE

3 to 4 sq mtr. per kg per coat. Two coats are recommended.

HEALTH AND SAFETY

Epoxy products generally cause irritation to the skin. Use of hand gloves by the workers is advised. Upon completion of day's work all the packing material should be burnt and buried.

QUALITY ASSURANCE

All “PERMA” branded products are manufactured under strict quality control supervision as per exact manufacturing specification. Should you find the behaviour of the product varying from the claims in the data sheets please stop the use of the product and contact the nearest Perma staff or distributor.

STATEMENT OF RESPONSIBILITY

Perma branded products when used in accordance with its current published directions for use performs as per its data sheets / catalogue. The manufacturer and the distributor will not be responsible for other materials and conditions of inferior workmanship.


 

 

 

.


 

 

 

 